|


GENTAUR BVBA
VAT BE0473327336
Av. de l Armee 68 B4
1040 Brussels
BELGIUM
Tel + 32 16 58 90
45
Fax + 32 16 50 90 45
GENTAUR France SARL
SIRET 48423788800017
Rue Lagrange, 9
75005 Paris,
France
Tel 01 43 25 01 50
Fax 01 43 25 01 60
GENTAUR Germany
Marienbongard 20
52074 Aachen,
Germany
Tel 0241 56 00
99 68
Fax 0241 56 00 47
88
GENTAUR
Pol Sp. Z.o.o.
Ulica Ogarna 15/19B
m2
80-826 GDANSK
Tel 00 48 58 760 77
08
Fax: 00 32 16 50 90
45
GENTAUR Italy
23015 Milano, Italy
Tel 02 36 00 65
93
Fax 02 36 00 65
94
Českį republika
Praha
+420246019719
Danmark
+4569918806
Finland Helsset
+358942419041
Ελλάς Αθήνα
+302111768494
Ireland Dublin
+35316526556
Luxembourg
+35220880274
Magyarorszįg
Budapest
+3619980547
Nederland
+31208080893
Norge
Oslo
+4721031366
Österreich
+43720880899
Sverige
Stockholm
+46852503438
Schweiz Züri
+41435006251
Northern America
Canada Montreal
+15149077481
US New York
+17185132983
Other Countries

0032 (0)16 41 44 07
|
OUR SUPPLIERS
KOMABIOTECH
301, Gayang
Technotown,
#1487 Gayang 3
dong, Gangseo-gu
Seoul 157-793,
KOREA
Sacace
Biotechnologies
S.r.l.
Via Scalabrini,
44
22100 Como Italy
Spherotech, Inc.
27845 Irma Lee Circle, Unit 101
Lake Forest, IL 60045
|
|
Exalpha
Biologicals,
Inc.
2 Shaker
Road,
Unit
B101
Shirley,
MA 01464
SCETI K.K
BIOSCIENCE Export DF Kasumigaseki Place,3-6-7 Kasumigaseki Chiyoda-ku, Tokyo 100-0013 JAPAN
|
EY
Laboratories, Inc.
Headquarters
107 N. Amphlett Blvd
San Mateo, CA. 94401 USA
EXBIO
Praha, a.s.
Nad
Safinou II 366
252 42 Vestec
Czech Republic
|
|
|
|
|
|
|

| |
| |
|
| Cat No. |
Size |
Conc. |
|
|
| BIO-91002 |
2x |
250 Reactions |
|
|
| BIO-91005 |
2x |
500 Reactions |
|
|
| BIO-91020 |
2x |
2000 Reactions |
|
|
|
| |
Please contact
info@bioline.com for Bulk,
Custom & OEM services.
|
| |
- Features and Benefits
- Unmatched sensitivity, earlier Ct detection
- Superior PCR Efficiency with sequence specific
probes
- High specificity, reproducibility and reduced
background
- Ideal for genotyping, multiplexing and gene
expression analysis
- Compatibility with all real-time PCR instruments
- Instrument Compatibility
ABI 7000, 7300, 7500, 7500 Fast, 7700, 7900, 7900HT,
StepOneTM, StepOneTM Plus, Roche LightCycler® 480,
Bio-Rad iCycler®, iQTM5 and MyiQTM, OpticonTM,
OpticonTM2, Chromo4TM, MiniOpticonTM, CFX96TM, CFX384TM,
Cepheid SmartCycler®, Qiagen (Corbett) Rotor-GeneTM
3000, Rotor-GeneTM6000, Eppendorf Mastercycler® ep
realplex, Techne Quantica®, Agilent (Stratagene)
Mx4000®, Mx3000P® and Mx3005P® (See
product
selection table).
- Description
SensiMix II Probe is a second-generation 2x mastermix
which has been formulated for superior sensitivity and
accurate real-time PCR using sequence specific probe
chemistries such as TaqMan®, Scorpion®, Assay On
Demand®, allelic discrimination and molecular beacon
probes. It uses the latest advances in enzyme chemistry
to deliver superior performance in genotyping, gene
expression analysis and multiplexing (Fig. 1). SensiMix
II Probe generates highly reproducible and reliable data
on all real-time PCR instruments.
SensiMix II Probe uses the hot-start properties of our
highly engineered proprietary DNA polymerase, SensiTaq,
giving high specificity and sensitivity and greatly
reducing non-specific amplification, resulting from
non-specific priming events during reaction setup and
initiation and increases overall reaction efficiency.
This is further enhanced with the use of our new buffer
formulation which has been designed to increase probe
and primers specific binding, leading to reduced
background, earlier cycle times (Cts) (Fig. 2) and
better allelic discrimination (Fig. 3).
A separate tube of ROX fluorescent dye is supplied in
order to facilitate the option of measuring this passive
reference signal on real-time instruments including the
ABI 7500 and 7900HT and Agilent (Stratagene) Mx3000P®
and Mx3005P® platforms.
- Volume
BIO-91002: 250 x 50µl Reactions: 5 x 1.25ml
BIO-91005: 500 x 50µl Reactions: 10 x 1.25ml
BIO-91020: 2000 x 50µl Reactions: 40 x 1.25ml
- Components
2x Reaction mix consisting of:
- Heat-activated DNA polymerase
- Ultra-pure dNTPs
- MgCl2 (6mM)
Plus separate vials of:
- 50mM MgCl2
- 25mM ROX Internal reference
- Kit Size
The kit size is based on a 50µl final reaction volume.
- Storage Conditions
6 months at -20°C. Avoid exposure of the ROX to light.
|
|
| |
|
|
|
|